<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-24 13-25-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 59 dBuV YLEX
Pilot RDS Phase Difference
7.4 kHz 2.3 kHz 65 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 18872 1,2028
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
1,3 dBr 3,67 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 2 (Affairs) 0 1 1 1 13:25, 24.10.2025
RT
"YleX Etusivu: Sonny "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 1,2028 Acquired: 2025/10/24 13.24.14 Total samples: 18872 Equivalent time: 0:15:43 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,1 dBr MIN: 1,3 dBr AVE: 3,67 dBr % above 12,2 dBr: 0,0 Last value: 2,9 dBr (2025/10/24 13.24.14) 13.10 13.12 13.14 13.16 13.18 13.20 13.22 13.24 0 2 4 6 Pm [dBr]